(818) 882-5000 [email protected] Northridge, CA 91324
AS9100D ISO 9001:2015

Averaging Temperature Sensors —Duct · HVAC · Air Handler · Tank

An averaging sensor integrates multiple sensing junctions or elements along its length, producing a single output that represents the average temperature across the measured space. Thermometrics supplies averaging thermocouples and Pt100 RTD assemblies for HVAC duct averaging, air handler coil temperature, large-tank average bulk temperature, and dryer/oven uniformity monitoring.

TC Averaging ProbeRTD Averaging ProbeDuct / HVACMulti-Junction or Wound WireFlexible or Rigid SheathCustom Lengths to 20ft
Product Configurations

Averaging Sensor Types

AVG-TC-1

Averaging Thermocouple — Multi-Junction

Multiple thermocouple junctions connected in series-parallel configuration within a single sheath. The resultant EMF is the true arithmetic average of all junctions — not a spatial average from a single measurement point. Junctions are distributed along the length at equal pitch. Type K standard, all standard types available.

2 to 8 JunctionsSeries-Parallel Type K / J / TMIMS or PVC Flex Equal or Custom Pitch
AVG-RTD-1

Averaging RTD — Wound-Wire Element

A Pt100 resistance element wound along the full sensing length, so the measured resistance represents the spatially averaged temperature along that length. Far more accurate averaging than a multi-junction TC approach when resistance is uniform along the sensor. Available in flexible silicone-jacketed or rigid stainless tube construction.

Wound-Wire Pt100Flexible or Rigid IEC 60751 Class B6" to 20ft Length 3-Wire Standard
AVG-RTD-2

Duct Averaging RTD — Rigid SS Capillary

A rigid stainless steel capillary tube housing a continuous Pt100 wound element, designed for direct insertion across an HVAC duct or air handler plenum. Flanged or NPT process connection at one end, sealed tip at the other. NEMA 4X connection head or direct lead wire. Available in 1ft increments from 1ft to 10ft insertion length.

Rigid 316SS Capillary1ft to 10ft Pt100 Class BHVAC / Air Handler NPT or Flanged
Specifications
ParameterAVG-TC-1AVG-RTD-1 & 2
Junctions / Element2 to 8 junctions, series-parallelContinuous wound Pt100
Length6" to 120"6" to 20ft (custom)
AccuracyASTM E230 Std toleranceIEC 60751 Class B (±0.3°C @ 0°C)
Sheath316SS, flex PVC, or MIMSSilicone flex or 316SS rigid
Temp RangeType K: −40°C to 400°C (PVC sheath)−50°C to 200°C (silicone flex)
Wire Config2-wire (junctions in parallel)3-wire standard; 4-wire available
Process ConnectionNPT, compression, or direct mountNPT, flanged, direct duct mount
ApplicationReturn air, furnace zone, tank bulkHVAC duct, air handler, dryer

Multi-Junction TC vs. Wound-Wire RTD

A multi-junction TC averages temperature at discrete, fixed points. A wound-wire RTD averages the entire length continuously. For HVAC duct averaging where spatial uniformity is unknown, the wound-wire RTD provides a more representative average. For furnace zone monitoring where specific measurement points are important, the multi-junction TC approach is preferred. Both technologies are available from Thermometrics.

HVAC & Building Automation

  • Supply air ductAVG-RTD-2, 24" to 72"
  • Return air plenumAVG-RTD-1 flex, to 10ft
  • Chilled water coilAVG-TC-1, Type T cryogenic
  • Hot water coilAVG-RTD-2, 3-wire, 4–20mA
  • Mixed air temperatureMulti-point AVG-RTD

Ready to Specify Your Sensor?

Talk directly to the engineering team that builds your assemblies. No bots, no call centers.