(818) 882-5000 [email protected] Northridge, CA 91324
AS9100D ISO 9001:2015

Thermocouple Wire & Cable Sensors —Bare Wire · Duplex · Extension Cable

Thermocouple wire sensors are the fundamental sensing element before installation into a sheath or housing. Thermometrics supplies thermocouple wire sensors in bare, PTFE-insulated, glass-braid, and ceramic-fiber constructions — as individual thermocouple pairs, duplex insulated cable, and extension-grade wire for runs from sensor to instrument.

Thermocouple Duplex WireExtension Grade WireHigh-Temp Glass/Ceramic BraidType K/J/T/E/N/R/SASTM E230 / IEC 60584PTFE · Fiberglass · Ceramic
Wire & Cable Types

Thermocouple Wire Product Guide

TypeDescriptionInsulationMax TempApplication
TC-TW-PTFEDuplex TC Wire — PTFE InsulatedPTFE individual + overall PFA jacket260°C continuousGeneral process; chemical-resistant runs; moisture-prone locations
TC-TW-FGDuplex TC Wire — Fibreglass InsulatedE-glass braid individual + overall braid480°C continuousOven and dryer leads; furnace door penetrations
TC-TW-CFDuplex TC Wire — Ceramic Fibre InsulatedHigh-alumina ceramic fibre braid1200°C maxThermocouple leads inside furnaces, kilns, combustion zones
TC-TW-SSDuplex TC Wire — SS OverbraidPTFE or FG + 304SS overbraid260–480°CMechanical protection; abrasion-prone installations
TC-EXT-PTFEExtension-Grade TC Cable — PTFEPTFE insulated, 20 AWG extension conductors260°CSensor-to-panel runs (not for sensing — extension grade conductors)
TC-EXT-PVCExtension-Grade TC Cable — PVCPVC, colour-coded per ANSI MC96.1105°CIndoor/conduit runs, control panels, standard plant wiring
TC-NM-RNoble Metal TC Wire — Type R (Pt-13%Rh/Pt)Alumina twin-bore insulation1480°CCalibration labs, noble metal assemblies, furnace Type R elements
TC-NM-SNoble Metal TC Wire — Type S (Pt-10%Rh/Pt)Alumina twin-bore insulation1480°CPrimary standard thermometry, glass furnace control elements
Wire Specifications
ParameterBase Metal WireNoble Metal Wire
Types AvailableK, J, T, E, NR, S, B (Pt-Rh alloys)
StandardASTM E230 / IEC 60584ASTM E230 / IEC 60584
ToleranceStandard; Special Limits availableClass 1; NIST-traced on request
AWG Sizes20, 24, 28, 30, 36, 40 AWG24, 28 AWG
Lot CertificationStandard with orderNIST-traceable EMF test
Colour CodeANSI MC96.1 (US) or IEC 60584-3ANSI/IEC on request
Custom StrandingSolid or 7-strandSolid only

Thermocouple Grade vs Extension Grade

Thermocouple-grade wire uses the actual thermocouple alloys (e.g., Chromel/Alumel for Type K) and is calibrated to sensing tolerances per ASTM E230. Extension-grade wire uses lower-cost alloys with the same Seebeck coefficient within a limited temperature range (typically 0°C to 200°C) and is only intended for the run from the sensor to the instrument panel. Never use extension-grade wire in the sensing zone — it introduces calibration error outside its rated range. Thermometrics supplies both grades; extension cables are colour-coded to match the sensing type per ANSI MC96.1.

Insulation Selection Guide

  • Below 105°C, dry locationPVC — lowest cost
  • Below 260°C, wet/chemicalPTFE — best chemical res.
  • 260–480°CFibreglass braid
  • 480–1200°CCeramic fibre braid
  • Inside furnace / flame zoneCeramic fibre only

Ready to Specify Your Sensor?

Talk directly to the engineering team that builds your assemblies. No bots, no call centers.