(818) 882-5000 [email protected] Northridge, CA 91324
AS9100D ISO 9001:2015

Spike & Profile Temperature Sensors —Furnace Profiling · Semiconductor · Heat Treat

Spike thermocouples and profile sensors are designed to travel through a furnace or oven with a product load, recording the temperature profile that the product experiences — not the ambient furnace temperature. Critical for validating furnace uniformity per AMS 2750, CQI-9, IPC-7711, and JEDEC reflow soldering standards.

Furnace Survey ProfilingAMS 2750 / CQI-9Semiconductor Wafer ProfilingReflow Solder OvenPush-Through Spike DesignData Logger Compatible
Product Series

Profile & Spike Sensor Types

TC-SPK-1

Push-Through Spike Thermocouple

A pointed-tip MIMS thermocouple designed to be pushed through foam, PCB, food product, or other materials to measure internal temperature during a process cycle. Exposed or lightly insulated tip, MIMS body, miniature TC connector. Used for thermal validation of reflow ovens, wave solder machines, conformal coating ovens, and food pasteurization tunnels.

Pointed TipMIMS 1/16" OD Type K / J / TMini TC Connector PCB / Food / Foam
TC-PRO-1

Furnace Survey Thermocouple

Survey thermocouples for AMS 2750 Temperature Uniformity Surveys (TUS) and System Accuracy Tests (SAT). Type K, N, or noble metal (R/S) per AMS 2750 Tables 1 and 2. Bayonet or compression fitting for easy installation at survey grid points. NIST-traceable calibration certificate required for each survey element.

AMS 2750 CompliantType K / N / R / S NIST Cal CertificateBayonet or NPT CQI-9 / NADCAP
RTD-PRO-1

Semiconductor Wafer Profile RTD

Pt100 profile sensors for semiconductor diffusion furnace tube temperature mapping. Small-OD 316SS or quartz-sheathed probe, multiple calibrated elements at defined depths, compatible with 200mm and 300mm wafer tube access ports. Class A, 4-wire, with NIST-traceable multipoint calibration at process temperatures.

Pt100 Class AQuartz or 316SS Sheath Multi-Point Calibration200mm / 300mm Tube Diffusion Furnace
AMS 2750 Compliance

Survey Thermocouple Requirements

AMS 2750 Instrument TypeTC Type (Allowed)Tolerance RequiredCal IntervalThermometrics Model
Type 1 (Noble)R or S±0.5°C or 0.1% whichever greaterAnnually or as usedTC-PRO-1 (R or S)
Type 2 (Base Metal)K, N, E±1.1°C or 0.4% whichever greater3 months or as usedTC-PRO-1 (K or N), TC-SPK-1
Type 3 (Base Metal SLE)K, N, E (SLE)±0.6°C or 0.2% whichever greater3 months or as usedTC-PRO-1 with SLE wire
Type 4 (Base Metal)K, J, N, T±2.2°C or 0.75% whichever greater6 monthsAny standard TC series
Type 5 (Noble)R, S, B±1.5°C or 0.25% whichever greaterAnnuallyTC-PRO-1 (R, S, or B)

Calibration Certificate Requirements

AMS 2750 and CQI-9 require that all survey thermocouples have a current NIST-traceable calibration certificate documenting the actual error at calibration temperature(s). Thermometrics issues calibration certificates with every TC-PRO-1 survey assembly. Certificates include sensor serial number, calibration date, reference standard traceability chain, and individual junction error at all test points. Recalibration service available on returned assemblies.

Ready to Specify Your Sensor?

Talk directly to the engineering team that builds your assemblies. No bots, no call centers.