(818) 882-5000 [email protected] Northridge, CA 91324
AS9100D ISO 9001:2015

Noble Metal Thermocouples —Type R, S & B

Platinum-rhodium thermocouples — Types R, S, and B — are the primary standard sensors for high-temperature measurement above 600°C. Thermometrics manufactures noble metal thermocouple assemblies with alumina and MgO insulation, calibrated to IEC 60584 and ASTM E230 with NIST-traceable certificates.

Type R (Pt-13%Rh / Pt)Type S (Pt-10%Rh / Pt)Type B (Pt-30%Rh / Pt-6%Rh)IEC 60584 CalibrationNIST-TraceableAMS 2750 / Furnace Standards
Noble Metal Types

Type R, S & B Technical Comparison

TypeConductorsRangeEMF @ 1000°CTolerance Class 1Primary Use
Type RPt-13%Rh (+) / Pt (−)0 to 1480°C10.506 mV±1.0°C or 0.25%Lab calibration, furnace monitoring, ITS-90 reference
Type SPt-10%Rh (+) / Pt (−)0 to 1480°C9.587 mV±1.0°C or 0.25%Silver/gold freezing point calibration, primary standard
Type BPt-30%Rh (+) / Pt-6%Rh (−)600 to 1820°C4.834 mV±0.5% above 800°CGlass furnace, ultra-high temperature; negligible output below 50°C
Configurations

Noble Metal Assembly Types

ConfigurationInsulationProtectionApplication
Bare wire, twin-bore alumina99.7% Al₂O₃ twin-bore rodMgO outer tube or noneLaboratory, calibration furnace
MIMS (Pt sheath)MgOPt or Pt-Rh sheathHigh-purity, low-contamination
Industrial assembly w/ headTwin-bore alumina + MgO outerInconel or ceramic protection tubePlant furnace, AMS 2750 control TC
Survey assembly (bayonet)Ceramic beads or twin-bore rodNone or alumina slip tubeAMS 2750 / CQI-9 TUS

Contamination Sensitivity

Noble metal thermocouple wire is extremely sensitive to contamination from metallic vapors, carbon, sulfur, hydrogen, and silicon. Thermometrics uses dedicated handling procedures, dedicated tooling, and protective packaging to prevent contamination during manufacturing. Alumina insulation (not silica) is specified for all noble metal assemblies to prevent SiO₂ reduction at the junction.

Calibration & Recalibration

  • Initial calibrationNIST-traceable, ITS-90
  • AMS 2750 interval (R/S)Annually or as-used
  • Uncertainty (Type S)±0.3°C at 1000°C typical
  • Repair & recalibrationAvailable — AS9100D

Ready to Specify Your Sensor?

Talk directly to the engineering team that builds your assemblies. No bots, no call centers.